Home > Services > 

Automotive EMC Test

Automotive EMC Test

Test Activities

We offer a high quality automotive EMC test service applying a great deal of knowledge and experience at No.6, No.7 anechoic chambers and No.8, No.9 shielded rooms for the automotive electric/electronic components. It is available to perform EMC testing for a number of Japan’s and international automotive manufacturers’ standards. The standards available have been shown below, however, if you have any questions on the details on the test requirements and others, please feel free to ask the Automotive Test Dept.

We

  • have been accredited by A2LA (The American Association for Laboratory Accreditation) per ISO/IEC 17025 and as the AEMCLRP laboratory.
  • have been recognized by the automotive manufacturers in the United States GM and FORD.
  • have been appointed by TUV Rheinland Japan.

Available Standards

GM Standards :GMW 3097
FORD Standards :EMC-CS-2009.1, ES-XW7T-1A278-AC
Chrysler Standards :CS-11979, DC-10614, DC-10615, DC-11224, DC-11225
UN ECE Regulations :ECE Regulation 10.03, 97, 116
EC Directive :2004/104/EC (~2009/19/EC)

Other Tests and Standards

JASO Standard : JASO D001-94 5.9
Handy Transmitter Immunity
Other Automotive Manufacturers’ Standards

Reference Standards

CISPR 25 and Its Similar Tests

CISPR 25 and Its Similar Tests

Radiated Emission : 150kHz - 2.5GHz
Conducted Emission (Voltage) : 150kHz - 200MHz
Conducted Emission (Current) : 150kHz - 200MHz
Low Frequency Conducted Emission : 20Hz - 200kHz
CISPR 25 and Its Similar Tests

ISO 11452-2, SAE J1113-21

Radiated Electromagnetic Field
(Absorber-lined shielded enclosure)
: 200MHz - 1GHz 200V/m
1GHz - 4GHz 300V/m
1.2GHz -1.4 GHz 600V/m
2.7GHz - 3.1GHz 600V/m
ISO 11452-2, SAE J1113-21

ISO 11452-3, SAE J1113-24

Radiated Electromagnetic Field
(TEM Cell)
: 10kHz - 200 MHz 200V/m
(10kHz - 400MHz)
ISO 11452-3, SAE J1113-24

ISO 11452-4, SAE J1113-4

Bulk Current Injection : 1MHz - 400 MHz 500mA
400MHz - 2GHz 200mA
Substitution method, Closed loop method
ISO 11452-4, SAE J1113-4

ISO 11452-5, SAE J1113-23

Radiated Electromagnetic Field
(50ΩStripline)
: 10kHz - 400MHz 200V/m
(10kHz - 1GHz)
ISO 11452-5, SAE J1113-23

ISO 11452-7, SAE J1113-3

Direct RF Power Injection : 250kHz - 500 MHz 0.8W
2A BAN, 30A BAN
ISO 11452-7, SAE J1113-3

ISO 11452-8

Magnetic Field Immunity : DC - 150 kHz Max 180 dBμA/m (1000A/m)
120 mm Loop Antenna
1.2 m Helmholtz Coil
ISO 11452-8, MIL-STD-461E RS101

SAE J1113-25

Radiated Electromagnetic Field
(Tri-late line)
: 10kHz - 512 MHz 200V/M
512MHz - 1GHz 100V/m
SAE J1113-25

ISO 7637-2/-3, ISO 16750, JASO D001-94 5.7

Voltage Transient Immunity : Pulse 1, 2a, 2b, 3a, 3b, 4, 5a, 5b
A-1, A-2, B-1, B-2, D-1, D-2, E Type
Voltage Transient Emission : Slow pulse,Fast pulse
Harness Immunity : CCC, DCC, ICC
ISO 7637-2/-3, ISO 16750, JASO D001-94 5.7

MIL-STD-461F and Others

Magnetic Field Emission
Frequency : 20Hz - 200 kHz
Antenna : 13.3 cm Loop sensor
MIL-STD-461E RE101

Damped Oscillation Tests

Output voltage 100 - 1500V
Oscillation frequency 1.5MHz
Half-wave peak value 10μs
Repetition frequency cycle: 0.4 - 400Hz
Damped Oscillation Tests

Impulse Tests

Square wave 50ns - 1μs, ±2kV
Triangular wave 1μs, ±2kV
Impulse Tests
Top